• Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter
  • Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter
  • Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter
  • Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter

Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter

Transport Package: Master Carton
Trademark: SD
Origin: China
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SD
HS Code
9018322000
Production Capacity
1000000

Product Description

Medical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis CatheterMedical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis CatheterMedical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis CatheterMedical Supplies Consumables Dialysis Double & Triple Lumen Hemodialysis Catheter
  • Intended Use

The Haemodialysis Catheters may be applicable to the one of following therapy:
- To supply the temporary blood vessel access in haemodialysis treatment; 
- Monitor of central venous pressure;
- Continuous or discontinuous venous transfusion.


The Catheter is surgically penetrated into three optional puncture points depended on the clinical requirement with Seldinger Technique. The Insertion Sites are :
1. Internal jugular vein; 
2. Subclavian vein; 
3. Femoral vein.
 
It is possible to be inserted inside the body for no more than 30 days. If duration exceeds 30 days, it may occur the risk of combining the catheter and inside tissue, which result in serious incident.
 
  • Contraindications

1. Infection or cut wound around the puncture area.
2. Dysfunction of blood coagulation.
3. During the anticoagulant treatment.
4. Symptoms of inadaptability to puncture operation, such as Pneumothorax, vein sclerosis.
5. Abnormal or unclear anatomical situation at the penetration area, such as sever emphysema, obviously inadaptability from previous operation
  • Complications

The clinical benefit of the use of HDC's must be evaluated against the recognized risks and complications of the procedure which include but are not limited to:
1. Infection, necrosis of the puncture point
2. Thrombus
3. Extravasation injury
4. Pheumothorax
5. Bleeding/hematoma
6. Arterial puncture
7. Air embolism
8. Hemothorax
9. Cardiac arrhythmia
10. Occlusion
  • Order Information

Number of Lumen O.D. Effective Length / mm
Fr mm
Single 7Fr 2.40 100, 130, 135, 150, 160, 200
8Fr 2.70 100, 130, 135, 150, 160, 200
Double 6.5Fr 2.20 50, 80, 100, 130, 160
8.5F 2.85 50, 80, 100, 110, 120, 130, 150, 160, 170, 200
10Fr 3.40 80, 100, 120, 130, 150, 160, 170, 200
11.5F 3.80 100, 120, 130, 135, 150, 160, 200, 240, 250
12Fr 4.00 100, 120, 130, 135, 150, 160, 200, 240, 250
14Fr 4.70 130, 150, 160, 190, 200, 240, 250
Triple 12Fr 4.00 130, 150, 160, 200, 240,250

The major components of the product package include central venous catheters, guidewire, dilator and puncture needle, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485, FSC