Principle of the SD-50D1 Pulse Oximeter is as follows:
Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Performance | SD-50DL1 | SD-50DL2 | SD-50D1 | SD-50D2 |
Display Mode | LED display |
Color display |
||
Power Supply | 1.5V (AAA size) alkaline batteries * 2 | |||
Power Consumption |
less than 25mA
|
less than 30mA | less than 80 mA | |
Dimension | 61(L) mm * 36(W) mm * 32(H) mm | 60(L) * 30.5(W) * 32.5 (H) mm | 61(L) * 36(W) * 32(H) mm |
60(L) * 30.5(W) * 32.5 (H) mm
|
Weight | About 60g (with the batteries) | About 50g (with the batteries)) | About 60g (with the batteries) | About 50g (with the batteries) |
Major Features
-- Integrated with SpO2 probe and processing display module
-- Small in volume light in weight and convenient in carrying
-- Operation of the product is simple ,low power consumption
-- SpO2 value display
-- Pulse rate value display, bar graph display
-- Pulse waveform display
-- The display mode can be changed
-- Screen brightness can be changed
-- Low-voltage indication
-- Automatically power off function:
when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
-- Display format can be saved after power off
Main performance
-- Display Mode: 0.96" Color display
-- SpO2 Measuring Range: 0%-100%, (the resolution is 1%).
-- Accuracy: 70%-100%: ±2% ,Below 70% unspecified.
-- PR Measuring Range: 30bpmï½250bpm, (the resolution is 1bpm)
-- Accuracy: ±2bpm or ±2% (select larger)
-- Measurement Performance in Weak Filling Condition:
-- SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 -- error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
-- Resistance to surrounding light: The deviation between the value measured in the -- condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
-- Power Consumption: less than 30mA
-- Voltage: DC 3.0V
-- Power Supply:1.5V (AAA size) alkaline batteries
Battery working hour: Theoretical number is 32 hours.
-- Safety Type:Interior Battery, BF Type