• High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
  • High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
  • High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
  • High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
  • High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
  • High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System

High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System

Certification: CE, ISO13485
Transport Package: Wood Carton
Trademark: SD
Origin: China
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
DR-570
HS Code
9022120000
Production Capacity
1000 Unit/Month

Product Description

 
DR-570 High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
Large view field 43cm X 43cm
A full sized view area with HD image can enable doctors to be more focused on lesion observation, and reduce radiation time for patients. HDR-570 with full size dynamic detector makes X-ray image reading much easier and more convenient. It is not affected by geometric distortion which is typical of image intensifiers.

Avoid misdiagnosis and missed diagnosis
Static DR sometimes have problem of misdiagnosis which resulted from overlaid images or improper positions. HDR-570 can provide multiple view angles with dynamic preview images, which helps to find out hidden lesions or correct the improper position in the low dose preview mode, together with spot film function to make a more precise diagnosis. The real-time replay and video recording function can also act as a powerful tool for lesion proof-check.

Digital radiography
Wide range of examination angles, as well as erect, lying, and oblique positions. Static imaging for radiographic examinations, Skull, Thorax, Abdomen, Vertebral Column, Pelvis, Upper and Lower Extremities and so on.

Digital fluoroscopy
Dynamic checking for fluoroscopy, esophagography, upper gastrointestinal (such as barium enemas, barium meals, and barium swallows), intravenous urography (IVP), HSG, T-tube cholangiography and so on.

Smart image stitching
With large field of view and advanced image processing workstation, Dynamic DR System can provide high defnition full-body x-ray image by smart image stitching function, especially helpful for orthopedics.
High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System
Technical Specifications
Dynamic Detector
Detector Technology
Full-Frame CCD
Effective View Field
17 x17 inch (430mm x 430mm)
Static Pixel Matrix
3072 x 3072
Dynamic Pixel Matrix
1024 x 1024
Spot-Film Pixel Matrix
3072 x 3072
Spot-Film Preparation Time
≤0.7s
Output Grayscale
14bit
Acquisition Time
≤6s
Preview Image Time
≤3s
Maximum Spatial Resolution
3.57lp/mm
X-ray Tube
Tube Focus
0.6mm / 1.2mm
Max Output Voltage
150kV
Heat Capacity
300kHU
Speed of Rotating Anode
≥2700r/min
Max speed of Rotating Anode
9700r/min
Output Power
27kW / 75kW
50KW Generator
Power Requirement
380V with 3 Phases Wires
Maximum Output Power
50kW
Output Voltage for Radiography
40kV - 150kV
Output Voltage for Fluoroscopy
40kV - 120kV
Output Current for Radiography
10mA - 650mA
Output Current for Fluoroscopy
0.5mA - 20mA
Range of mAs
0.4mAs - 630mAs
Auto Brightness Selection Function (ABS)
Remote Control Table
Positioning for Chest-Exam / Table-Exam by Electric Control
Table Dimension (L x W x H)
2100mm x 880mm x 865mm
Table Lateral Movement
250mm
SID
1500mm
Table Rotation Range
-15° - +90°
Tube Column Rotation Range
-45° - +45°
High Voltage Cables of X-ray Machine
Length: 8m
Grid
Grid Density
40lp/cm
Grid Ratio
10:01
Focus
100cm
Collimator
Max Work Dose
150kVp
Power
150W (24VAC)
Auto-close time
30s
Brightness
≥160lux (100cm)
Workstation
CPU
Dual-Core 3.0G
RAM
2GB
Communication Network Card
1000m
Hard Disk
500G
Display
24-inch
CD/DVD recording/burning
Software
Imaging Part Indicator, Tissue Equalization, Filter Correction, Grayscale Transform, Window/Level Adjustment, Gamma Correction, ROI Equalization Black/White Reversion, Image Segmentation, Mark, Enhancement, Smoothing Sharpening, Compression, Magnification, Graphic Text Report, Printing Software Supports Image Stitching for Long Spine and Long Leg Views Film Printing, Supports Standard
DICOM 3.0 Laser Film Printer DICOM 3.0 Format, Compatible to Transfer to PACS
High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray SystemWorkshop
High Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray SystemHigh Frequency Digital Dynamic Detector Radiography & Fluoroscopy X Ray System


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485, FSC